8xH200 SXM-141GB (MaxQ), MLPerf v4.1 mixtral-8x7b Offline: 48987.9 output tok/s at 5854.3 W mean = 0.1195 J/output token
Fields
benchmarks/h200-8x-mlperf-v4-1-maxq-mixtral-8x7b-offline-energy-per-tokenNotes
MoE IS NEARLY TWICE AS ENERGY-FASTER PER TOKEN THAN THE DENSE 70B ON THIS EXACT NODE: 0.1195 J/token vs 0.2299 J/token for Llama 2 70B - a 48% reduction - and it draws essentially the SAME power (5854.3 W vs 5806.9 W, under 1% apart). THE HONEST READING, because 'MoE is cheaper' is the conclusion a reader will want and the data does not fully support it. What this shows is that PER TOKEN, Mixtral-8x7B extracts roughly twice the tokens from a watt-second than a dense 70B does, because only ~12.9B of its 46.7B parameters are active per token. What it does NOT show is that MoE is cheaper per USEFUL token, per byte of weight shipped, or per model of comparable quality: Mixtral-8x7B and Llama 2 70B are different models at different capability levels, and all 46.7B of Mixtral's weights still have to sit in HBM. Treat this as tokens-per-joule evidence, which is strong, and not as a model-selection verdict, which it is not. A SECOND CONFOUND TO STATE: Mixtral-8x7b and llama2-70b-99.9 have DIFFERENT input/output sequence lengths fixed by their MLPerf reference implementations, and MoE routing cost scales differently with sequence length than dense GEMM cost does. The J/token comparison holds the hardware constant but not the workload shape, so it is not a perfectly matched A/B. REPRODUCIBLE: FALSE - same private-PTDaemon reason as the sibling records.
ENERGY-FIELD BACKFILL 2026-10-05 (schema authority pass, agent w5-schema). The joules_per_token metric and the energy_basis / power_w / power_scope / power_cap / clock_lock_mhz / thermal_state fields have existed in schemas/benchmark.schema.json since they were drafted, and until this commit EVERY ONE OF THEM WAS UNUSED: zero records set power_w, power_scope or thermal_state, and joules_per_token had zero records while the watts and joules travelled as prose inside `unit`. This record's own notes were already asking for the fix ('RECOMMENDED SCHEMA CHANGE: this record wants a first-class joules_per_token metric rather than watts smuggled into the unit string'). The fields are now populated from facts this record already documented, and the stored throughput value and metric are UNCHANGED - the joules figure is recorded ALONGSIDE the throughput, not instead of it, because the throughput is independently measured and the joules are derived from it. node, same reasoning as the sibling records. null, NOT 700 - factory TGP is not a measured cap. steady: post-ramp min 2377.9 W against max 6300.9 W across 2831 samples is a held plateau.